The authors present an implant prosthesis procedure that uses screws on one-piece implants connected with a titanium pin at their abutment level and one supporter titanium bar in order to guarantee immediate stabilization. These can be implanted and fitted with customized temporary crowns in a single surgical procedure, restoring function and aesthetics and consenting recovery of the bone deficit with reduced healing times and limited patient discomfort. One-piece wide-diameter titanium screw implants with thread measurements of 2.1 and 2.6 mm (smaller diameter) up to diameter of 4.5 mm with one abutment of 2.0 and 2.5 mm respectively, were positioned and splinted by intraoral welding. One-piece titanium implants were used together with a pin (needle) titanium implant as supporting structure to achieve deep stabilization. The Scialom-like pin has a diameter of 1.2 mm and it is long enough to reach deep cortical bone that is “bicorticalism”. The One-piece implant is tightly connected to the needle implant by means of Mondani intra-oral welding technique. In severely atrophic anterior maxilla, the use of this method allows the immediate loading of a fixed resin prosthesis soon after surgery. These implants yielded satisfactory functional and aesthetic outcome in bone-deficient upper anterior sectors, without invasive regenerative procedures. The low invasiveness of this approach also consents rapid healing, reduced biological burden and greater patient benefit.

Pasqualini, M., Lauritano, D., Rossi, F., Dal Carlo, L., Shulman, M., Meynardi, F., et al. (2018). Rehabilitations with immediate loading of one-piece implants stabilized with intraoral welding. JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS, 32(2), 19-26.

Rehabilitations with immediate loading of one-piece implants stabilized with intraoral welding

Lauritano, D.
Co-primo
Membro del Collaboration Group
;
2018

Abstract

The authors present an implant prosthesis procedure that uses screws on one-piece implants connected with a titanium pin at their abutment level and one supporter titanium bar in order to guarantee immediate stabilization. These can be implanted and fitted with customized temporary crowns in a single surgical procedure, restoring function and aesthetics and consenting recovery of the bone deficit with reduced healing times and limited patient discomfort. One-piece wide-diameter titanium screw implants with thread measurements of 2.1 and 2.6 mm (smaller diameter) up to diameter of 4.5 mm with one abutment of 2.0 and 2.5 mm respectively, were positioned and splinted by intraoral welding. One-piece titanium implants were used together with a pin (needle) titanium implant as supporting structure to achieve deep stabilization. The Scialom-like pin has a diameter of 1.2 mm and it is long enough to reach deep cortical bone that is “bicorticalism”. The One-piece implant is tightly connected to the needle implant by means of Mondani intra-oral welding technique. In severely atrophic anterior maxilla, the use of this method allows the immediate loading of a fixed resin prosthesis soon after surgery. These implants yielded satisfactory functional and aesthetic outcome in bone-deficient upper anterior sectors, without invasive regenerative procedures. The low invasiveness of this approach also consents rapid healing, reduced biological burden and greater patient benefit.
Articolo in rivista - Articolo scientifico
Immediate loading; Intraoral welding; Narrow-diameter screw; One-piece implant; Pin implant;
English
2018
32
2
19
26
reserved
Pasqualini, M., Lauritano, D., Rossi, F., Dal Carlo, L., Shulman, M., Meynardi, F., et al. (2018). Rehabilitations with immediate loading of one-piece implants stabilized with intraoral welding. JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS, 32(2), 19-26.
File in questo prodotto:
File Dimensione Formato  
3 - REHABILITATIONS WITH IMMEDIATE LOADING OF ONE-PIECE IMPLANTS.pdf

Solo gestori archivio

Descrizione: Articolo principale
Dimensione 2.83 MB
Formato Adobe PDF
2.83 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/192904
Citazioni
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
Social impact