The purpose of the present study was to evaluate whether the difference between blood pressure measured in the clinic or physician's office and the average daytime blood pressure accurately reflects the blood pressure response of the patient to the physician ("white coat effect" or "white coat hypertension"). We studied 28 hypertensive outpatients (mean age, 41.8+/-11.2 years; age range, 21 to 64 years) of 35 consecutive patients attending our hypertension clinic, in whom (1) continuous noninvasive finger blood pressure was recorded before and during the visit, (2) blood pressure was measured according to the Riva-Rocci-Korotkoff method (mercury sphygmomanometer) with the patient in the supine position, and (3) daytime ambulatory blood pressure was monitored with a SpaceLabs 90207 device. The peak blood pressure increase recorded directly during the visit was compared with the difference between clinic and daytime average ambulatory blood pressures. Compared with previsit values, peak increases in finger systolic and diastolic blood pressures during the visit to the clinic were 38.2+/-3.1 and 20.7+/-1.6 mm Hg, respectively (mean+/-SEM, P<.01 for both). Daytime average systolic and diastolic blood pressures were 135.5+/-2.5 and 89.2+/-1.9 mm Hg, with both lower than the corresponding clinic blood pressure values (146.6+/-3.6 and 94.9+/-2.2 mm Hg, P<.01). These differences, however, were <30% of the peak finger blood pressure increases during the physician's visit, to which these increases showed no relation. Although the visit to the physician's office was associated with tachycardia (9.0+/-1.6 bpm, P<.01), there was no difference between clinic and daytime average heart rates. These data indicate that the clinic-daytime average blood pressure difference does not reflect the alerting reaction and the pressure response elicited by the physician's visit and thus is not a reliable measure of the white coat effect

Parati, G., Ulian, L., Santucciu, C., Omboni, S., Mancia, G. (1998). Difference between clinic and daytime blood pressure is not a measure of the white coat effect. HYPERTENSION, 31(5), 1185-1189 [10.1161/01.HYP.31.5.1185].

Difference between clinic and daytime blood pressure is not a measure of the white coat effect

Parati, G;Mancia, G
1998

Abstract

The purpose of the present study was to evaluate whether the difference between blood pressure measured in the clinic or physician's office and the average daytime blood pressure accurately reflects the blood pressure response of the patient to the physician ("white coat effect" or "white coat hypertension"). We studied 28 hypertensive outpatients (mean age, 41.8+/-11.2 years; age range, 21 to 64 years) of 35 consecutive patients attending our hypertension clinic, in whom (1) continuous noninvasive finger blood pressure was recorded before and during the visit, (2) blood pressure was measured according to the Riva-Rocci-Korotkoff method (mercury sphygmomanometer) with the patient in the supine position, and (3) daytime ambulatory blood pressure was monitored with a SpaceLabs 90207 device. The peak blood pressure increase recorded directly during the visit was compared with the difference between clinic and daytime average ambulatory blood pressures. Compared with previsit values, peak increases in finger systolic and diastolic blood pressures during the visit to the clinic were 38.2+/-3.1 and 20.7+/-1.6 mm Hg, respectively (mean+/-SEM, P<.01 for both). Daytime average systolic and diastolic blood pressures were 135.5+/-2.5 and 89.2+/-1.9 mm Hg, with both lower than the corresponding clinic blood pressure values (146.6+/-3.6 and 94.9+/-2.2 mm Hg, P<.01). These differences, however, were <30% of the peak finger blood pressure increases during the physician's visit, to which these increases showed no relation. Although the visit to the physician's office was associated with tachycardia (9.0+/-1.6 bpm, P<.01), there was no difference between clinic and daytime average heart rates. These data indicate that the clinic-daytime average blood pressure difference does not reflect the alerting reaction and the pressure response elicited by the physician's visit and thus is not a reliable measure of the white coat effect
Articolo in rivista - Articolo scientifico
Adult; Blood Pressure Determination; Female; Humans; Hypertension; Male; Middle Aged; Stress, Physiological; Blood Pressure; Blood Pressure Monitoring, Ambulatory
English
1998
31
5
1185
1189
none
Parati, G., Ulian, L., Santucciu, C., Omboni, S., Mancia, G. (1998). Difference between clinic and daytime blood pressure is not a measure of the white coat effect. HYPERTENSION, 31(5), 1185-1189 [10.1161/01.HYP.31.5.1185].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/190981
Citazioni
  • Scopus 125
  • ???jsp.display-item.citation.isi??? 115
Social impact