The paper describes the Faraday room that shields the CUORE experiment against electromagnetic fields, from 50 Hz up to high frequency. Practical constraints led to choose panels made of light shielding materials. The seams between panels were optimized with simulations to minimize leakage. Measurements of shielding performance show attenuation of a factor 15-20 at 50 Hz, and a factor 1000 above 1 kHz up to about 100 MHz.
Bucci, C., Carniti, P., Cassina, L., Gotti, C., Pelosi, A., Pessina, G., et al. (2017). The Faraday room of the CUORE experiment. JOURNAL OF INSTRUMENTATION, 12(12) [10.1088/1748-0221/12/12/P12013].
The Faraday room of the CUORE experiment
Carniti, P;Cassina, L;Gotti, C
;Pessina, G;
2017
Abstract
The paper describes the Faraday room that shields the CUORE experiment against electromagnetic fields, from 50 Hz up to high frequency. Practical constraints led to choose panels made of light shielding materials. The seams between panels were optimized with simulations to minimize leakage. Measurements of shielding performance show attenuation of a factor 15-20 at 50 Hz, and a factor 1000 above 1 kHz up to about 100 MHz.File in questo prodotto:
Non ci sono file associati a questo prodotto.