New methods for efficient and unambiguous interconnection between electronic position sensitive detectors and target units based on nuclear photographic emulsion films have been developed. The application to the OPERA experiment,that aims at detecting VμâVÏoscillations in the CNGS neutrino beam,is reported in this paper. In order to reduce background due to latent tracks collected before installation in the detector,on-site large-scale treatments of the emulsions (ârefreshingâ) have been applied. Changeable Sheet (CSd) packages,each made of a doublet of emulsion films,have been designed,assembled and coupled to the OPERA target units (âECC bricksâ). A device has been built to print X-ray spots for accurate interconnection both within the CSd and between the CSd and the related ECC brick. Sample emulsion films have been extensively scanned with state-of-the-art automated optical microscopes. Efficient track-matching and powerful background rejection have been achieved in tests with electronically tagged penetrating muons. Further improvement of in-doublet film alignment was obtained by matching the pattern of low-energy electron tracks. The commissioning of the overall OPERA alignment procedure is in progress
Anokhina, A., Aoki, S., Ariga, A., Arrabito, L., Autiero, D., Badertscher, A., et al. (2008). Emulsion sheet doublets as interface trackers for the OPERA experiment. JOURNAL OF INSTRUMENTATION, 3(7) [10.1088/1748-0221/3/07/P07005].
Emulsion sheet doublets as interface trackers for the OPERA experiment
New methods for efficient and unambiguous interconnection between electronic position sensitive detectors and target units based on nuclear photographic emulsion films have been developed. The application to the OPERA experiment,that aims at detecting VμâVÏoscillations in the CNGS neutrino beam,is reported in this paper. In order to reduce background due to latent tracks collected before installation in the detector,on-site large-scale treatments of the emulsions (ârefreshingâ) have been applied. Changeable Sheet (CSd) packages,each made of a doublet of emulsion films,have been designed,assembled and coupled to the OPERA target units (âECC bricksâ). A device has been built to print X-ray spots for accurate interconnection both within the CSd and between the CSd and the related ECC brick. Sample emulsion films have been extensively scanned with state-of-the-art automated optical microscopes. Efficient track-matching and powerful background rejection have been achieved in tests with electronically tagged penetrating muons. Further improvement of in-doublet film alignment was obtained by matching the pattern of low-energy electron tracks. The commissioning of the overall OPERA alignment procedure is in progress
Detector alignment and calibration methods (Lasers,Sources,Particle-beams); Detector design and construction technologies and materials; Large detector systems for particle and astroparticle physics; Particle tracking detectors; Instrumentation; Mathematical Physics
Anokhina, A., Aoki, S., Ariga, A., Arrabito, L., Autiero, D., Badertscher, A., et al. (2008). Emulsion sheet doublets as interface trackers for the OPERA experiment. JOURNAL OF INSTRUMENTATION, 3(7) [10.1088/1748-0221/3/07/P07005].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/189183
Citazioni
55
46
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.