A non-destructive neutron analysis technique performed at the IMAT beamline of the STFC (Science and Technology Facility Council), UK, is presented. In this experiment, neutrons of different energy have been exploited to obtain a tomographic reconstruction of a biomineralic sample, more specifically a cultured pearl, by using a time-resolving pixel camera, the MicroChannel Plate (MCP) detector, utilizing an array of 2 × 2 Timepix readout chips. The MCP camera is capable of energy-resolved two-dimensional mapping of neutron transmission with a spatial resolution of ~ 55 μm. By using a Simultaneous Iterative Reconstruction Technique (SIRT), virtual sections of the internal part of the sample have been created, thus revealing several features inside its bulk. The crystallographic phase map via Bragg edge analysis, showing a phase fraction distribution on the entire specimen, has been generated as well. Finally, 3D volume rendering of the pearl is presented.

Vitucci, G., Minniti, T., Di Martino, D., Musa, M., Gori, L., Micieli, D., et al. (2018). Energy-resolved neutron tomography of an unconventional cultured pearl at a pulsed spallation source using a microchannel plate camera. MICROCHEMICAL JOURNAL, 137, 473-479 [10.1016/j.microc.2017.12.002].

Energy-resolved neutron tomography of an unconventional cultured pearl at a pulsed spallation source using a microchannel plate camera

Vitucci, G
;
Di Martino, D;Musa, M;Gorini, G
2018

Abstract

A non-destructive neutron analysis technique performed at the IMAT beamline of the STFC (Science and Technology Facility Council), UK, is presented. In this experiment, neutrons of different energy have been exploited to obtain a tomographic reconstruction of a biomineralic sample, more specifically a cultured pearl, by using a time-resolving pixel camera, the MicroChannel Plate (MCP) detector, utilizing an array of 2 × 2 Timepix readout chips. The MCP camera is capable of energy-resolved two-dimensional mapping of neutron transmission with a spatial resolution of ~ 55 μm. By using a Simultaneous Iterative Reconstruction Technique (SIRT), virtual sections of the internal part of the sample have been created, thus revealing several features inside its bulk. The crystallographic phase map via Bragg edge analysis, showing a phase fraction distribution on the entire specimen, has been generated as well. Finally, 3D volume rendering of the pearl is presented.
Articolo in rivista - Articolo scientifico
Cultured pearl; Energy resolved imaging; Microchannel plate; Neutron imaging detector; Neutron phase mapping;
Cultured pearl; Energy resolved imaging; Microchannel plate; Neutron imaging detector; Neutron phase mapping; Analytical Chemistry; Spectroscopy
English
2018
137
473
479
reserved
Vitucci, G., Minniti, T., Di Martino, D., Musa, M., Gori, L., Micieli, D., et al. (2018). Energy-resolved neutron tomography of an unconventional cultured pearl at a pulsed spallation source using a microchannel plate camera. MICROCHEMICAL JOURNAL, 137, 473-479 [10.1016/j.microc.2017.12.002].
File in questo prodotto:
File Dimensione Formato  
Vitucci_MicrochemJ2018.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 966.82 kB
Formato Adobe PDF
966.82 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/182809
Citazioni
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 12
Social impact