Study Objectives: In heart failure (HF), we observed two patterns of hyperpnea during Cheyne-Stokes respiration with central sleep apnea (CSR-CSA): a positive pattern where end-expiratory lung volume remains at or above functional residual capacity, and a negative pattern where it falls below functional residual capacity. We hypothesized the negative pattern is associated with worse HF. Methods: Patients with HF underwent polysomnography. During CSR-CSA, hyperpnea, apnea-hyperpnea cycle, and lung to finger circulation times (LFCT) were measured. Plasma N-terminal prohormone of brain natriuretic peptide (NT-proBNP) concentration and left ventricular ejection fraction (LVEF) were assessed. Results: Of 33 patients with CSR-CSA (31 men, mean age 68 years), 9 had a negative hyperpnea pattern. There was no difference in age, body mass index, and apnea-hypopnea index between groups. Patients with a negative pattern had longer hyperpnea time (39.5 ± 6.4 versus 25.8 ± 5.9 seconds, P < .01), longer cycle time (67.8 ± 15.9 versus 51.7 ± 9.9 seconds, P < .01), higher NT-proBNP concentrations (2740 [6769] versus 570 [864] pg/ml, P = .01), and worse New York Heart Association class (P = .02) than those with a positive pattern. LFCT and LVEF did not differ between groups. Conclusions: Patients with HF and a negative CSR-CSA pattern have evidence of worse cardiac function than those with a positive pattern. Greater positive expiratory pressure during hyperpnea is likely generated during the negative pattern and might support stroke volume in patients with worse cardiac function. Commentary: A commentary on this article appears in this issue on page 1227. Clinical Trial Registration: The trial is registered with Current Controlled Trials (www.controlled-trials.com; ISRCTN67500535) and Clinical Trials (www. clinicaltrials.gov; NCT01128816).
Perger, E., Inami, T., Lyons, O., Alshaer, H., Smith, S., Floras, J., et al. (2017). Distinct patterns of hyperpnea during cheyne-stokes respiration: Implication for cardiac function in patients with heart failure. JOURNAL OF CLINICAL SLEEP MEDICINE, 13(11), 1235-1241 [10.5664/jcsm.6788].
Distinct patterns of hyperpnea during cheyne-stokes respiration: Implication for cardiac function in patients with heart failure
Perger, Elisa;Parati, Gianfranco;
2017
Abstract
Study Objectives: In heart failure (HF), we observed two patterns of hyperpnea during Cheyne-Stokes respiration with central sleep apnea (CSR-CSA): a positive pattern where end-expiratory lung volume remains at or above functional residual capacity, and a negative pattern where it falls below functional residual capacity. We hypothesized the negative pattern is associated with worse HF. Methods: Patients with HF underwent polysomnography. During CSR-CSA, hyperpnea, apnea-hyperpnea cycle, and lung to finger circulation times (LFCT) were measured. Plasma N-terminal prohormone of brain natriuretic peptide (NT-proBNP) concentration and left ventricular ejection fraction (LVEF) were assessed. Results: Of 33 patients with CSR-CSA (31 men, mean age 68 years), 9 had a negative hyperpnea pattern. There was no difference in age, body mass index, and apnea-hypopnea index between groups. Patients with a negative pattern had longer hyperpnea time (39.5 ± 6.4 versus 25.8 ± 5.9 seconds, P < .01), longer cycle time (67.8 ± 15.9 versus 51.7 ± 9.9 seconds, P < .01), higher NT-proBNP concentrations (2740 [6769] versus 570 [864] pg/ml, P = .01), and worse New York Heart Association class (P = .02) than those with a positive pattern. LFCT and LVEF did not differ between groups. Conclusions: Patients with HF and a negative CSR-CSA pattern have evidence of worse cardiac function than those with a positive pattern. Greater positive expiratory pressure during hyperpnea is likely generated during the negative pattern and might support stroke volume in patients with worse cardiac function. Commentary: A commentary on this article appears in this issue on page 1227. Clinical Trial Registration: The trial is registered with Current Controlled Trials (www.controlled-trials.com; ISRCTN67500535) and Clinical Trials (www. clinicaltrials.gov; NCT01128816).File | Dimensione | Formato | |
---|---|---|---|
10281-181457.pdf
accesso aperto
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Dimensione
1.56 MB
Formato
Adobe PDF
|
1.56 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.