We present an enhancement of the OSEM (ordered set expectation maximization) algorithm for 3D PET reconstruction, which we call the inter-update Metz filtered OSEM (IMF-OSEM). The IMF-OSEM algorithm incorporates filtering action into the image updating process in order to improve the quality of the reconstruction. With this technique, the multiplicative correction image--ordinarily used to update image estimates in plain OSEM--is applied to a Metz-filtered version of the image estimate at certain intervals. In addition, we present a software implementation that employs several high-speed features to accelerate reconstruction. These features include, firstly, forward and back projection functions which make full use of symmetry as well as a fast incremental computation technique. Secondly, the software has the capability of running in parallel mode on several processors. The parallelization approach employed yields a significant speed-up, which is nearly independent of the amount of data. Together, these features lead to reasonable reconstruction times even when using large image arrays and non-axially compressed projection data. The performance of IMF-OSEM was tested on phantom data acquired on the GE Advance scanner. Our results demonstrate that an appropriate choice of Metz filter parameters can improve the contrast-noise balance of certain regions of interest relative to both plain and post-filtered OSEM, and to the GE commercial reprojection algorithm software

Jacobson, M., Levkovitz, R., Ben-Tal, A., Thielemans, K., Spinks, T., Belluzzo, D., et al. (2000). Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering. PHYSICS IN MEDICINE AND BIOLOGY, 45(8), 2417-2439 [10.1088/0031-9155/45/8/325].

Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering

Gilardi, MC;
2000

Abstract

We present an enhancement of the OSEM (ordered set expectation maximization) algorithm for 3D PET reconstruction, which we call the inter-update Metz filtered OSEM (IMF-OSEM). The IMF-OSEM algorithm incorporates filtering action into the image updating process in order to improve the quality of the reconstruction. With this technique, the multiplicative correction image--ordinarily used to update image estimates in plain OSEM--is applied to a Metz-filtered version of the image estimate at certain intervals. In addition, we present a software implementation that employs several high-speed features to accelerate reconstruction. These features include, firstly, forward and back projection functions which make full use of symmetry as well as a fast incremental computation technique. Secondly, the software has the capability of running in parallel mode on several processors. The parallelization approach employed yields a significant speed-up, which is nearly independent of the amount of data. Together, these features lead to reasonable reconstruction times even when using large image arrays and non-axially compressed projection data. The performance of IMF-OSEM was tested on phantom data acquired on the GE Advance scanner. Our results demonstrate that an appropriate choice of Metz filter parameters can improve the contrast-noise balance of certain regions of interest relative to both plain and post-filtered OSEM, and to the GE commercial reprojection algorithm software
Articolo in rivista - Articolo scientifico
3D PET, ordered set expectation maximization
English
2000
45
8
2417
2439
none
Jacobson, M., Levkovitz, R., Ben-Tal, A., Thielemans, K., Spinks, T., Belluzzo, D., et al. (2000). Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering. PHYSICS IN MEDICINE AND BIOLOGY, 45(8), 2417-2439 [10.1088/0031-9155/45/8/325].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/16767
Citazioni
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 51
Social impact