OBJECTIVES: To assess quantitatively the relationship between nocturnal blood pressure (BP) fall and 24-h BP variability; to propose a new method for computing 24-h BP variability, devoid of the contribution from nocturnal BP fall; and to verify the clinical value of this method. METHODS AND RESULTS: We analysed 3863 ambulatory BP recordings, and computed: (1) the standard deviation (SD) of 24-h BP directly from all individual readings and as a weighted mean of daytime and night-time SD (wSD); and (2) the size of nocturnal BP fall. Left ventricular mass index (LVMI) was assessed by echocardiography in 339 of the patients. The 24-h SD of BP was significantly greater than the 24-h wSD. Nocturnal BP fall was strongly and directly related to 24-h SD, the relationship with 24-h wSD being much weaker and inverse. The difference between SD and wSD was almost exclusively determined by the size of nocturnal BP fall. wSD of systolic BP was significantly related to LVMI, while 24-h SD was not. CONCLUSION: Conventional 24-h SD of BP is markedly influenced by nocturnal BP fall. The weighted 24-h SD of BP removes the mathematical interference from night-time BP fall and correlates better with end-organ damage, therefore it may be considered as a simple index of 24-h BP variability superior to conventional 24-h SD. © 2007 Lippincott Williams & Wilkins, Inc.

Bilo, G., Giglio, A., Styczkiewicz, K., Caldara, G., Maronati, A., Kawecka Jaszcz, K., et al. (2007). A new method for assessing 24-h blood pressure variability after excluding the contribution of nocturnal blood pressure fall. JOURNAL OF HYPERTENSION, 25(10), 2058-2066 [10.1097/HJH.0b013e32829c6a60].

A new method for assessing 24-h blood pressure variability after excluding the contribution of nocturnal blood pressure fall

BILO, GRZEGORZ
Primo
;
GIGLIO, ALESSIA MAFALDA
Secondo
;
CALDARA, GIANLUCA;MANCIA, GIUSEPPE
Penultimo
;
PARATI, GIANFRANCO
Ultimo
2007

Abstract

OBJECTIVES: To assess quantitatively the relationship between nocturnal blood pressure (BP) fall and 24-h BP variability; to propose a new method for computing 24-h BP variability, devoid of the contribution from nocturnal BP fall; and to verify the clinical value of this method. METHODS AND RESULTS: We analysed 3863 ambulatory BP recordings, and computed: (1) the standard deviation (SD) of 24-h BP directly from all individual readings and as a weighted mean of daytime and night-time SD (wSD); and (2) the size of nocturnal BP fall. Left ventricular mass index (LVMI) was assessed by echocardiography in 339 of the patients. The 24-h SD of BP was significantly greater than the 24-h wSD. Nocturnal BP fall was strongly and directly related to 24-h SD, the relationship with 24-h wSD being much weaker and inverse. The difference between SD and wSD was almost exclusively determined by the size of nocturnal BP fall. wSD of systolic BP was significantly related to LVMI, while 24-h SD was not. CONCLUSION: Conventional 24-h SD of BP is markedly influenced by nocturnal BP fall. The weighted 24-h SD of BP removes the mathematical interference from night-time BP fall and correlates better with end-organ damage, therefore it may be considered as a simple index of 24-h BP variability superior to conventional 24-h SD. © 2007 Lippincott Williams & Wilkins, Inc.
Articolo in rivista - Articolo scientifico
Ambulatory blood pressure monitoring; Arterial hypertension; Blood pressure variability; Left ventricular mass; Nocturnal blood pressure fall; Adult; Aged; Analysis of Variance; Blood Pressure; Blood Pressure Monitoring, Ambulatory; Circadian Rhythm; Echocardiography; Female; Heart Ventricles; Humans; Hypertension; Male; Middle Aged; Internal Medicine; Physiology; Cardiology and Cardiovascular Medicine
English
2007
25
10
2058
2066
none
Bilo, G., Giglio, A., Styczkiewicz, K., Caldara, G., Maronati, A., Kawecka Jaszcz, K., et al. (2007). A new method for assessing 24-h blood pressure variability after excluding the contribution of nocturnal blood pressure fall. JOURNAL OF HYPERTENSION, 25(10), 2058-2066 [10.1097/HJH.0b013e32829c6a60].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/163465
Citazioni
  • Scopus 199
  • ???jsp.display-item.citation.isi??? 185
Social impact