PURPOSE: To describe the degradation effects produced by respiratory organ and lesion motion on PET/CT images and to define the role of respiratory gated (RG) 4D-PET/CT techniques to compensate for such effects. METHODS: Based on the literature and on our own experience, technical recommendations and clinical indications for the use of RG 4D PET/CT have been outlined. RESULTS: RG 4D-PET/CT techniques require a state of the art PET/CT scanner, a respiratory monitoring system and dedicated acquisition and processing protocols. Patient training is particularly important to obtain a regular breathing pattern. An adequate number of phases has to be selected to balance motion compensation and statistical noise. RG 4D PET/CT motion free images may be clinically useful for tumour tissue characterization, monitoring patient treatment and target definition in radiation therapy planning. CONCLUSIONS: RG 4D PET/CT is a valuable tool to improve image quality and quantitative accuracy and to assess and measure organ and lesion motion for radiotherapy planning.

Bettinardi, V., Picchio, M., Di Muzio, N., Gianolli, L., Gilardi, M., Messa, M. (2010). Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques. RADIOTHERAPY AND ONCOLOGY, 96(3), 311-316 [10.1016/j.radonc.2010.07.014].

Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques

GILARDI, MARIA CARLA;MESSA, MARIA CRISTINA
2010

Abstract

PURPOSE: To describe the degradation effects produced by respiratory organ and lesion motion on PET/CT images and to define the role of respiratory gated (RG) 4D-PET/CT techniques to compensate for such effects. METHODS: Based on the literature and on our own experience, technical recommendations and clinical indications for the use of RG 4D PET/CT have been outlined. RESULTS: RG 4D-PET/CT techniques require a state of the art PET/CT scanner, a respiratory monitoring system and dedicated acquisition and processing protocols. Patient training is particularly important to obtain a regular breathing pattern. An adequate number of phases has to be selected to balance motion compensation and statistical noise. RG 4D PET/CT motion free images may be clinically useful for tumour tissue characterization, monitoring patient treatment and target definition in radiation therapy planning. CONCLUSIONS: RG 4D PET/CT is a valuable tool to improve image quality and quantitative accuracy and to assess and measure organ and lesion motion for radiotherapy planning.
Articolo in rivista - Articolo scientifico
Respiratory organ motion; Respiratory gated 4D-PET/CT; Radiotherapy
English
2010
96
3
311
316
none
Bettinardi, V., Picchio, M., Di Muzio, N., Gianolli, L., Gilardi, M., Messa, M. (2010). Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques. RADIOTHERAPY AND ONCOLOGY, 96(3), 311-316 [10.1016/j.radonc.2010.07.014].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/16257
Citazioni
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 49
Social impact