Since many years the Milano Gran Sasso collaboration is developing large mass calorimeters for Double Beta Decay and Dark Matter searches, employing TeO2 crystals as absorber elements. Recently, we have focused our attention on the improvement of the detector resolution: an efficient dumping suspension and the implementation of a new cold electronics device, have strongly suppressed the main sources of noise. The increase in SIN ratio has been of almost an order of magnitude and the resolution achieved is competitive with that of Ge diodes for gamma -rays detection, while a FWHM of 3.2 +/-0.3 keV has been obtained for 5.4 MeV alpha particles, the best result with any kind of detector. (C) 2001 Elsevier Science B.V. All rights reserved

Vanzini, M., Alessandrello, A., Brofferio, C., Bucci, C., Coccia, E., Cremonesi, O., et al. (2001). High-resolution bolometers for rare events detection. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 461(1-3), 293-296 [10.1016/S0168-9002(00)01228-6].

High-resolution bolometers for rare events detection

BROFFERIO, CHIARA;Cremonesi, O;FIORINI, ETTORE;NUCCIOTTI, ANGELO ENRICO LODOVICO;PAVAN, MAURA;Pessina, G;Previtali, E;ZANOTTI, LUIGI ERNESTO
2001

Abstract

Since many years the Milano Gran Sasso collaboration is developing large mass calorimeters for Double Beta Decay and Dark Matter searches, employing TeO2 crystals as absorber elements. Recently, we have focused our attention on the improvement of the detector resolution: an efficient dumping suspension and the implementation of a new cold electronics device, have strongly suppressed the main sources of noise. The increase in SIN ratio has been of almost an order of magnitude and the resolution achieved is competitive with that of Ge diodes for gamma -rays detection, while a FWHM of 3.2 +/-0.3 keV has been obtained for 5.4 MeV alpha particles, the best result with any kind of detector. (C) 2001 Elsevier Science B.V. All rights reserved
Articolo in rivista - Articolo scientifico
double beta decay; bolometers; energy resolution
English
2001
461
1-3
293
296
none
Vanzini, M., Alessandrello, A., Brofferio, C., Bucci, C., Coccia, E., Cremonesi, O., et al. (2001). High-resolution bolometers for rare events detection. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 461(1-3), 293-296 [10.1016/S0168-9002(00)01228-6].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/154199
Citazioni
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
Social impact