Background. Titanium is the gold standard for dental implants, since it has demonstrated excellent biocompatibility and osseointegration properties. The rate of osseointegration is however affected by the surface morphology and peri-implant infections may affect fixture and the long-term osseointegration outcome. Thus chemical composition of a coating at the implant-abutment junction (IAJ) surface is expected to play a key role in preventing bacterial infection. Purpose. In the present study a new antimicrobial polysiloxane coating functionalized with chlorexidine digluconate (PXT) has been tested in an in vitro model. Materials and methods. Twenty implants were coated in the internal chamber with PXT and twenty were used as controls. Results and conclusions. Ten of the coated implants, preliminarily tested against Gram positive and negative bacteria and fungi, showed a complete inactivation of the microbial species after a 15 min contact. On the remaining ten treated implants a series of microbiological tests and PCR analysis, after contamination of the implant external medium, in which the implant have been immersed, with genetic modified Tannerella forsythia (TF) and Porphyromonas Gingivalis (PG), leads to the conclusion that the coating is capable of inactivating the microbial species penetrating the internal of the implant through the implant abutment junction.

Lauritano, D., Bignozzi, C., Pazzi, D., Cura, F., Carinci, F. (2017). Efficacy of a new coating of implantabutment connections in reducing bacterial loading: An in vitro study. ORAL & IMPLANTOLOGY, 10(1), 1-10 [10.11138/orl/2017.10.1.001].

Efficacy of a new coating of implantabutment connections in reducing bacterial loading: An in vitro study

LAURITANO, DORINA
Primo
;
2017

Abstract

Background. Titanium is the gold standard for dental implants, since it has demonstrated excellent biocompatibility and osseointegration properties. The rate of osseointegration is however affected by the surface morphology and peri-implant infections may affect fixture and the long-term osseointegration outcome. Thus chemical composition of a coating at the implant-abutment junction (IAJ) surface is expected to play a key role in preventing bacterial infection. Purpose. In the present study a new antimicrobial polysiloxane coating functionalized with chlorexidine digluconate (PXT) has been tested in an in vitro model. Materials and methods. Twenty implants were coated in the internal chamber with PXT and twenty were used as controls. Results and conclusions. Ten of the coated implants, preliminarily tested against Gram positive and negative bacteria and fungi, showed a complete inactivation of the microbial species after a 15 min contact. On the remaining ten treated implants a series of microbiological tests and PCR analysis, after contamination of the implant external medium, in which the implant have been immersed, with genetic modified Tannerella forsythia (TF) and Porphyromonas Gingivalis (PG), leads to the conclusion that the coating is capable of inactivating the microbial species penetrating the internal of the implant through the implant abutment junction.
Articolo in rivista - Articolo scientifico
Antimicrobial siloxane coating; Implant-abutment connection; Peri-implantitis; Dentistry (all)
English
2017
10
1
1
10
open
Lauritano, D., Bignozzi, C., Pazzi, D., Cura, F., Carinci, F. (2017). Efficacy of a new coating of implantabutment connections in reducing bacterial loading: An in vitro study. ORAL & IMPLANTOLOGY, 10(1), 1-10 [10.11138/orl/2017.10.1.001].
File in questo prodotto:
File Dimensione Formato  
290 O and I LAURITANO.pdf

accesso aperto

Dimensione 304.27 kB
Formato Adobe PDF
304.27 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/152191
Citazioni
  • Scopus 28
  • ???jsp.display-item.citation.isi??? ND
Social impact