Abstract We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The time resolution of MCPs exceeds anything that has been previously used in calorimeters and, if exploited effectively, could aid in the event reconstruction at high luminosity colliders. Several prototypes of photodetectors with the amplification stage based on MCPs were exposed to cosmic rays and to 491 MeV electrons at the INFN-LNF Beam-Test Facility. The time resolution and the efficiency of the MCPs are measured as a function of the particle multiplicity, and the results used to model the response to high-energy showers.

Brianza, L., Cavallari, F., Del Re, D., Gelli, S., Ghezzi, A., Gotti, C., et al. (2015). Response of microchannel plates to single particles and to electromagnetic showers. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 797, 216-221 [10.1016/j.nima.2015.06.057].

Response of microchannel plates to single particles and to electromagnetic showers

BRIANZA, LUCA;GHEZZI, ALESSIO;GOTTI, CLAUDIO;GOVONI, PIETRO;MARTELLI, ARABELLA;MARZOCCHI, BADDER;PIGAZZINI, SIMONE;ROVELLI, CHIARA ILARIA;TABARELLI DE FATIS, TOMMASO
;
2015

Abstract

Abstract We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The time resolution of MCPs exceeds anything that has been previously used in calorimeters and, if exploited effectively, could aid in the event reconstruction at high luminosity colliders. Several prototypes of photodetectors with the amplification stage based on MCPs were exposed to cosmic rays and to 491 MeV electrons at the INFN-LNF Beam-Test Facility. The time resolution and the efficiency of the MCPs are measured as a function of the particle multiplicity, and the results used to model the response to high-energy showers.
Articolo in rivista - Articolo scientifico
Calorimetry; Electromagnetic showers; Microchannel plates; Secondary emission; Time response; Nuclear and High Energy Physics; Instrumentation
English
2015
797
216
221
57858
none
Brianza, L., Cavallari, F., Del Re, D., Gelli, S., Ghezzi, A., Gotti, C., et al. (2015). Response of microchannel plates to single particles and to electromagnetic showers. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 797, 216-221 [10.1016/j.nima.2015.06.057].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/141767
Citazioni
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 26
Social impact