The purpose of this study was to evaluate 115 "Conus" uncemented stems at an average follow-up of 6 years (2-9 years). Seventeen patients were lost at follow-up for a final number of 98 stems in 75 patients. The clinical outcome of 71 hips (72%) was graded excellent, 25 (25%) were good, one (2%) fair and one (2%) poor. The average Harris Hip Score increased from 49.35 before operation to 96.30 at the time of the last follow-up. None of the stems implanted required a revision for aseptic or septic loosening. Cortical hypertrophy or radiolucencies were never seen in any of the stems evaluated. Heterotopic ossification was seen in one hip (1%). Modification of the calcar was observed in 29 hips (30%) and they consisted in a slight rounding off of the proximal medial edge of the cut femoral neck. These results encourage the use of this versatile stem which showed a good primary and secondary stability, with a good load distribution along the femur.

Cherubino, P., Zatti, G., D'Angelo, F., Murena, L., Monzeglio, D. (2007). "Conus" uncemented stem in developmental hip dysplasia. HIP INTERNATIONAL, 17(2), S134-S137 [10.5301/hip.2008.4213].

"Conus" uncemented stem in developmental hip dysplasia

ZATTI, GIOVANNI;
2007

Abstract

The purpose of this study was to evaluate 115 "Conus" uncemented stems at an average follow-up of 6 years (2-9 years). Seventeen patients were lost at follow-up for a final number of 98 stems in 75 patients. The clinical outcome of 71 hips (72%) was graded excellent, 25 (25%) were good, one (2%) fair and one (2%) poor. The average Harris Hip Score increased from 49.35 before operation to 96.30 at the time of the last follow-up. None of the stems implanted required a revision for aseptic or septic loosening. Cortical hypertrophy or radiolucencies were never seen in any of the stems evaluated. Heterotopic ossification was seen in one hip (1%). Modification of the calcar was observed in 29 hips (30%) and they consisted in a slight rounding off of the proximal medial edge of the cut femoral neck. These results encourage the use of this versatile stem which showed a good primary and secondary stability, with a good load distribution along the femur.
Articolo in rivista - Articolo scientifico
Cementless stem; Conical stem; Total hip replacement;
English
2007
17
2
S134
S137
none
Cherubino, P., Zatti, G., D'Angelo, F., Murena, L., Monzeglio, D. (2007). "Conus" uncemented stem in developmental hip dysplasia. HIP INTERNATIONAL, 17(2), S134-S137 [10.5301/hip.2008.4213].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/14082
Citazioni
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
Social impact