AIM: To evaluate the learning effect of short-wavelength automated perimetry (SWAP) on a group of patients with ocular hypertension experienced with standard automated perimetry (SAP). METHODS: Thirty patients with ocular hypertension underwent 5 full-threshold SWAP tests at intervals of 7±2 days. The parameters investigated to detect a learning effect were duration, the perimetric indices, and the number of points with a P of <5% and 1% in the total and pattern deviation maps. Differences in learning effect were also evaluated by comparing the sensitivities of central, paracentral, and peripheral areas, hemifields and quadrants. RESULTS: Learning effects were demonstrated for mean defect (P<0.0001, analysis of variance), duration (P=0.0001), the number of points with P<5% in the pattern deviation map (P=0.003), and short fluctuations (P=0.03). The effect was greater in the peripheral than in central areas (P=0.04). Mean defect was the most sensitive parameter, for which the learning effect was statistically significant between the first and the fifth test. CONCLUSIONS: The results of this study demonstrate a significant learning effect at full-threshold SWAP. This may limit the efficacy of this kind of perimetry in detecting early glaucoma, and should therefore be carefully considered when creating normative databases for new SWAP strategies. Copyright © 2006 by Lippincott Williams & Wilkins.

Rossetti, L., Fogagnolo, P., Miglior, S., Centofanti, M., Vetrugno, M., Orzalesi, N. (2006). The learning effect of short-wavelength automated perimetry in patients with ocular hypertension. JOURNAL OF GLAUCOMA, 15(5), 399-404 [10.1097/01.ijg.0000212261.12112.99].

The learning effect of short-wavelength automated perimetry in patients with ocular hypertension

MIGLIOR, STEFANO;
2006

Abstract

AIM: To evaluate the learning effect of short-wavelength automated perimetry (SWAP) on a group of patients with ocular hypertension experienced with standard automated perimetry (SAP). METHODS: Thirty patients with ocular hypertension underwent 5 full-threshold SWAP tests at intervals of 7±2 days. The parameters investigated to detect a learning effect were duration, the perimetric indices, and the number of points with a P of <5% and 1% in the total and pattern deviation maps. Differences in learning effect were also evaluated by comparing the sensitivities of central, paracentral, and peripheral areas, hemifields and quadrants. RESULTS: Learning effects were demonstrated for mean defect (P<0.0001, analysis of variance), duration (P=0.0001), the number of points with P<5% in the pattern deviation map (P=0.003), and short fluctuations (P=0.03). The effect was greater in the peripheral than in central areas (P=0.04). Mean defect was the most sensitive parameter, for which the learning effect was statistically significant between the first and the fifth test. CONCLUSIONS: The results of this study demonstrate a significant learning effect at full-threshold SWAP. This may limit the efficacy of this kind of perimetry in detecting early glaucoma, and should therefore be carefully considered when creating normative databases for new SWAP strategies. Copyright © 2006 by Lippincott Williams & Wilkins.
Articolo in rivista - Articolo scientifico
Glaucoma, SWAP
English
2006
15
5
399
404
none
Rossetti, L., Fogagnolo, P., Miglior, S., Centofanti, M., Vetrugno, M., Orzalesi, N. (2006). The learning effect of short-wavelength automated perimetry in patients with ocular hypertension. JOURNAL OF GLAUCOMA, 15(5), 399-404 [10.1097/01.ijg.0000212261.12112.99].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/13483
Citazioni
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
Social impact