In ion beam therapy, Positron Emission Tomography (PET) imaging can be applied to provide a consistency check of the delivered treatment with respect to the treatment plan. Treatment verification relies on the comparison between a PET distribution measured during or after treatment delivery (measured PET) and a PET simulation calculated on the basis of the treatment plan (expected PET). The method is challenged by the poor image quality of the measured PET, which may result in a low sensitivity to detectable mismatches between planned and applied treatment. In this work we propose the application of a motion-aware 4D Maximum Likelihood (ML) reconstruction strategy for PET-based treatment verification in ion beam therapy. This approach is specifically tested on simulated clinical-like scenarios, as well as on a real clinical dataset. The measured PET and the expected PET are interpreted as two different motion states of a 4D PET dataset. The idea is to estimate the deformation field mapping the expected PET onto the measured PET as a measure of mismatches. An enhanced measured PET is therefore obtained by warping the expected PET according to the estimated motion field. Clinical-like scenarios were reproduced by means of Monte Carlo simulations corresponding to a hypo-fractionated carbon ion treatment of liver tumour. The measured PET was attributed to different simulations introducing positioning mismatches by means of rigid translations, to be compared to the reference expected PET simulation without mismatch. Real clinical dataset include PET data acquired shortly after treatment at a dedicated PET-CT scanner installed at HIT (Heidelberg Ion beam Therapy Center, Germany), in comparison to the corresponding expected PET coming from Monte Carlo simulations. The accuracy of mismatch estimation and the robustness to noise are shown.

Gianoli, C., Ricotti, R., DE BERNARDI, E., Riboldi, M., Bauer, J., Debus, J., et al. (2016). Clinical investigations of a 4D ML reconstruction strategy for PET-based treatment verification in ion beam therapy. In 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014 (pp.1-4). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2014.7430904].

Clinical investigations of a 4D ML reconstruction strategy for PET-based treatment verification in ion beam therapy

DE BERNARDI, ELISABETTA;
2016

Abstract

In ion beam therapy, Positron Emission Tomography (PET) imaging can be applied to provide a consistency check of the delivered treatment with respect to the treatment plan. Treatment verification relies on the comparison between a PET distribution measured during or after treatment delivery (measured PET) and a PET simulation calculated on the basis of the treatment plan (expected PET). The method is challenged by the poor image quality of the measured PET, which may result in a low sensitivity to detectable mismatches between planned and applied treatment. In this work we propose the application of a motion-aware 4D Maximum Likelihood (ML) reconstruction strategy for PET-based treatment verification in ion beam therapy. This approach is specifically tested on simulated clinical-like scenarios, as well as on a real clinical dataset. The measured PET and the expected PET are interpreted as two different motion states of a 4D PET dataset. The idea is to estimate the deformation field mapping the expected PET onto the measured PET as a measure of mismatches. An enhanced measured PET is therefore obtained by warping the expected PET according to the estimated motion field. Clinical-like scenarios were reproduced by means of Monte Carlo simulations corresponding to a hypo-fractionated carbon ion treatment of liver tumour. The measured PET was attributed to different simulations introducing positioning mismatches by means of rigid translations, to be compared to the reference expected PET simulation without mismatch. Real clinical dataset include PET data acquired shortly after treatment at a dedicated PET-CT scanner installed at HIT (Heidelberg Ion beam Therapy Center, Germany), in comparison to the corresponding expected PET coming from Monte Carlo simulations. The accuracy of mismatch estimation and the robustness to noise are shown.
poster + paper
Nuclear and High Energy Physics; Radiology, Nuclear Medicine and Imaging
English
IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
2014
2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
9781479960972
2016
1
4
7430904
none
Gianoli, C., Ricotti, R., DE BERNARDI, E., Riboldi, M., Bauer, J., Debus, J., et al. (2016). Clinical investigations of a 4D ML reconstruction strategy for PET-based treatment verification in ion beam therapy. In 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014 (pp.1-4). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2014.7430904].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/132924
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
Social impact