In vivo studies of blood circulation pathologies have great medical relevance and need methods for the characterization of time varying flows at high spatial and time resolution in small animal models. We test here the efficacy of the combination of image correlation techniques and single plane illumination microscopy (SPIM) in characterizing time varying flows in vitro and in vivo. As indicated by numerical simulations and by in vitro experiments on straight capillaries, the complex analytical form of the cross-correlation function for SPIM detection can be simplified, in conditions of interest for hemodynamics, to a superposition of Gaussian components, easily amenable to the analysis of variable flows. The possibility to select a wide field of view with a good spatial resolution along the collection optical axis and to compute the cross-correlation between regions of interest at varying distances on a single time stack of images allows one to single out periodic flow components from spurious peaks on the cross-correlation functions and to infer the duration of each flow component. We apply this cross-correlation analysis to the blood flow in Zebrafish embryos at 4 days after fertilization, measuring the average speed and the duration of the systolic and diastolic phases.

Marquezin, C., Ceffa, N., Cotelli, F., Collini, M., Sironi, L., Chirico, G. (2016). Image Cross-Correlation Analysis of Time Varying Flows. ANALYTICAL CHEMISTRY, 88(14), 7115-7122 [10.1021/acs.analchem.6b01143].

Image Cross-Correlation Analysis of Time Varying Flows

CEFFA, NICOLÒ GIOVANNI
Secondo
;
COLLINI, MADDALENA;SIRONI, LAURA
Penultimo
;
CHIRICO, GIUSEPPE
Ultimo
2016

Abstract

In vivo studies of blood circulation pathologies have great medical relevance and need methods for the characterization of time varying flows at high spatial and time resolution in small animal models. We test here the efficacy of the combination of image correlation techniques and single plane illumination microscopy (SPIM) in characterizing time varying flows in vitro and in vivo. As indicated by numerical simulations and by in vitro experiments on straight capillaries, the complex analytical form of the cross-correlation function for SPIM detection can be simplified, in conditions of interest for hemodynamics, to a superposition of Gaussian components, easily amenable to the analysis of variable flows. The possibility to select a wide field of view with a good spatial resolution along the collection optical axis and to compute the cross-correlation between regions of interest at varying distances on a single time stack of images allows one to single out periodic flow components from spurious peaks on the cross-correlation functions and to infer the duration of each flow component. We apply this cross-correlation analysis to the blood flow in Zebrafish embryos at 4 days after fertilization, measuring the average speed and the duration of the systolic and diastolic phases.
Articolo in rivista - Articolo scientifico
Spim, Cross-correlation, Flurescence, microfluidics
English
2016
88
14
7115
7122
reserved
Marquezin, C., Ceffa, N., Cotelli, F., Collini, M., Sironi, L., Chirico, G. (2016). Image Cross-Correlation Analysis of Time Varying Flows. ANALYTICAL CHEMISTRY, 88(14), 7115-7122 [10.1021/acs.analchem.6b01143].
File in questo prodotto:
File Dimensione Formato  
article.pdf

Solo gestori archivio

Dimensione 3.17 MB
Formato Adobe PDF
3.17 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/132766
Citazioni
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
Social impact