The purpose of this prospective clinical study was to evaluate the survival rate (SVR - i.e. fixtures still in place at the end of the observation period) and success rate (SCR - i.e. bone resorption around implant neck) of an implant system characterized by cylindrical and tapered implants, both provided with an internal hexagonal connection. In the period between January 1996 and October 2011, 52 implants with internal hexagonal connection were inserted in 21 females and 31 males, mean age 54±11 years. The mean post-surgical follow-up was 44.6±34.4 months. Several parameters were evaluated as potential outcome conditioners: Age, gender, smoking, replaced tooth, periodontal disease, fixture shape (i.e. cylindrical or tapered), jaw location (i.e. maxilla or mandible), bone graft, immediate loading, post-extractive placement, type of prosthesis (i.e. single crown or bridge), edentulism, implant diameter and length. An SPSS statistical program was used and Cox regression analysis performed. SVR was 100% since no fixtures were lost. SCR, expressed through the mean marginal bone loss, was 77%. No significant differences were found, for most of the parameters analyzed, with the exception of prosthetic bridges, where implants supporting this type of rehabilitation showed a worse clinical outcome in comparison to single crown rehabilitations. Internal hexagonal connection is a reliable tool for oral rehabilitation.

Andreasi Bassi, M., Lopez, M., Confalone, L., Gaudio, R., Lombardo, L., Lauritano, D. (2016). Clinical outcome of a two-piece implant system with an internal hexagonal connection: A prospective study. JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS, 30(2), 7-12.

Clinical outcome of a two-piece implant system with an internal hexagonal connection: A prospective study

LAURITANO, DORINA
Ultimo
2016

Abstract

The purpose of this prospective clinical study was to evaluate the survival rate (SVR - i.e. fixtures still in place at the end of the observation period) and success rate (SCR - i.e. bone resorption around implant neck) of an implant system characterized by cylindrical and tapered implants, both provided with an internal hexagonal connection. In the period between January 1996 and October 2011, 52 implants with internal hexagonal connection were inserted in 21 females and 31 males, mean age 54±11 years. The mean post-surgical follow-up was 44.6±34.4 months. Several parameters were evaluated as potential outcome conditioners: Age, gender, smoking, replaced tooth, periodontal disease, fixture shape (i.e. cylindrical or tapered), jaw location (i.e. maxilla or mandible), bone graft, immediate loading, post-extractive placement, type of prosthesis (i.e. single crown or bridge), edentulism, implant diameter and length. An SPSS statistical program was used and Cox regression analysis performed. SVR was 100% since no fixtures were lost. SCR, expressed through the mean marginal bone loss, was 77%. No significant differences were found, for most of the parameters analyzed, with the exception of prosthetic bridges, where implants supporting this type of rehabilitation showed a worse clinical outcome in comparison to single crown rehabilitations. Internal hexagonal connection is a reliable tool for oral rehabilitation.
Articolo in rivista - Articolo scientifico
Bone; Connection; Hexagon; Implants; Internal; Rate; Success; Survival;
implants, connection, internal, hexagon, bone, success, survival, rate
English
2016
30
2
7
12
reserved
Andreasi Bassi, M., Lopez, M., Confalone, L., Gaudio, R., Lombardo, L., Lauritano, D. (2016). Clinical outcome of a two-piece implant system with an internal hexagonal connection: A prospective study. JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS, 30(2), 7-12.
File in questo prodotto:
File Dimensione Formato  
264 CLINICAL OUTCOME OF A TWO-PIECE IMPLANT SYSTEM WITH AN INTERNAL HEXAGONAL CONNECTION.pdf

Solo gestori archivio

Descrizione: Articolo principale
Dimensione 306.7 kB
Formato Adobe PDF
306.7 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/128993
Citazioni
  • Scopus 55
  • ???jsp.display-item.citation.isi??? 25
Social impact