Several osmotic cataract models as well as human diabetic lenses were tested by nuclear magnetic resonance spectroscopy and imaging. Both longitudinal (T1) and transverse (T2) relaxation times increased with increase in lens hydration. Therefore proton magnetic resonance imaging (MRI) can be used to detect changes of the biophysical environment of water proton in the lens. T2-weighted imaging sequence (spin-echo) can be used to differentiate lenses with hydrational changes since they exhibit higher signal intensity (because of long T2) than normal lenses at the same TE (echo time). A greater contrast can be achieved with the inversion-recovery sequence, which, in addition to contribution from T2, also incorporates T1 and proton density terms. Proton MRI is potentially useful for the detection of pre-cataractous changes

Cheng, H., Yeh, L., Barnett, P., Miglior, S., Eagon, J., González, G., et al. (1987). Proton magnetic resonance imaging of the ocular lens. EXPERIMENTAL EYE RESEARCH, 45(6), 875-882 [10.1016/S0014-4835(87)80103-3].

Proton magnetic resonance imaging of the ocular lens

MIGLIOR, STEFANO;
1987

Abstract

Several osmotic cataract models as well as human diabetic lenses were tested by nuclear magnetic resonance spectroscopy and imaging. Both longitudinal (T1) and transverse (T2) relaxation times increased with increase in lens hydration. Therefore proton magnetic resonance imaging (MRI) can be used to detect changes of the biophysical environment of water proton in the lens. T2-weighted imaging sequence (spin-echo) can be used to differentiate lenses with hydrational changes since they exhibit higher signal intensity (because of long T2) than normal lenses at the same TE (echo time). A greater contrast can be achieved with the inversion-recovery sequence, which, in addition to contribution from T2, also incorporates T1 and proton density terms. Proton MRI is potentially useful for the detection of pre-cataractous changes
Articolo in rivista - Articolo scientifico
Aged; Aged, 80 and over; Animals; Cataract; Diabetes Mellitus; Female; Humans; Lens, Crystalline; Magnetic Resonance Imaging; Male; Middle Aged; Rabbits; Water
English
1987
45
6
875
882
none
Cheng, H., Yeh, L., Barnett, P., Miglior, S., Eagon, J., González, G., et al. (1987). Proton magnetic resonance imaging of the ocular lens. EXPERIMENTAL EYE RESEARCH, 45(6), 875-882 [10.1016/S0014-4835(87)80103-3].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.