A new intraoral luting technique between electroformed galvanic gold caps (AGC) and a metallic framework for a Cement-retained Implant-supported Metal-resin-fixed Complete-denture (CIMC) is presented. The peculiarity is the different prosthetic design with the metallic framework that is 1.5 mm shorter than the margin of the galvanic caps. As a consequence, the conventional thick prosthesis margin (AGC, cement for the luting phase, framework)is modified into a thin AGC prosthesis seal (0,3 mm) just beyond the apical limit of the aesthetic material. Passive fit is achieved during the intraoral luting phase between the framework and the galvanic caps. In this retrospective study we analyzed the periodontal response (plaque index and sulcus bleeding index) between patients treated with the conventional technique and patients treated with the new technique. The results (36 months followup) show that the new prosthetic techniques allows better periodontal health and in both groups, according to Literature, we found a positive correlation between plaque index and sulcus bleeding index. In conclusion, the new procedure is efficient, standardized, and enhances aesthetics and periodontal health.
(2009). Valutazione della risposta parodontale in due tipologie di protesi implantare. (Tesi di dottorato, Università degli Studi di Milano-Bicocca, 2009).
Valutazione della risposta parodontale in due tipologie di protesi implantare
SARTORI, MATTEO
2009
Abstract
A new intraoral luting technique between electroformed galvanic gold caps (AGC) and a metallic framework for a Cement-retained Implant-supported Metal-resin-fixed Complete-denture (CIMC) is presented. The peculiarity is the different prosthetic design with the metallic framework that is 1.5 mm shorter than the margin of the galvanic caps. As a consequence, the conventional thick prosthesis margin (AGC, cement for the luting phase, framework)is modified into a thin AGC prosthesis seal (0,3 mm) just beyond the apical limit of the aesthetic material. Passive fit is achieved during the intraoral luting phase between the framework and the galvanic caps. In this retrospective study we analyzed the periodontal response (plaque index and sulcus bleeding index) between patients treated with the conventional technique and patients treated with the new technique. The results (36 months followup) show that the new prosthetic techniques allows better periodontal health and in both groups, according to Literature, we found a positive correlation between plaque index and sulcus bleeding index. In conclusion, the new procedure is efficient, standardized, and enhances aesthetics and periodontal health.File | Dimensione | Formato | |
---|---|---|---|
phd_unimib_708156_1.pdf
accesso aperto
Tipologia di allegato:
Doctoral thesis
Dimensione
51.15 kB
Formato
Adobe PDF
|
51.15 kB | Adobe PDF | Visualizza/Apri |
phd_unimib_708156_2.pdf
accesso aperto
Tipologia di allegato:
Doctoral thesis
Dimensione
2.94 MB
Formato
Adobe PDF
|
2.94 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.