Purpose: To evaluate a new dark-blood late gadolinium enhancement (LGE) technique called “T(Rho) And Magnetization transfer and INvErsion Recovery” (TRAMINER) for the ability to detect myocardial LGE versus standard “bright-blood” inversion recovery (SIR) imaging. Materials and Methods: This Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study included 40 patients (62 ± 14 years [mean ± standard deviation (SD)], 29 males) with suspected myocardial infarction (MI) referred for the assessment of myocardial viability. The patients underwent a 1.5T cardiac magnetic resonance imaging (MRI) including postcontrast SIR and TRAMINER acquisitions. Normalized images were evaluated by two readers. Subjective (3-point Likert scale) and objective image qualities were compared using Mann–Whitney U-test and paired t-test, respectively. Interobserver agreement, LGE detection rate, and level of certainty were compared using Cohen's kappa, Wilcoxon-test, and Mann–Whitney U-test, respectively. Results are reported as mean ± SD or mean [95% confidence interval]. Results: Overall, image quality was rated similar between TRAMINER and SIR; however, TRAMINER performed better on a visual assessment of the ability to differentiate LGE from blood (Likert scale: 3.0 [3.0–3.0] vs. 2.0 [1.7–2.2], P < 0.0001). TRAMINER provided significantly higher signal intensity range (69.8 ± 10.2 vs. 9.6 ± 7.6, P < 0.0001) and a 4-fold higher signal intensity ratio (4.2 ± 1.9 vs. 1.1 ± 0.1, P < 0.0001) between LGE and blood signals. TRAMINER detected more patients (19/40 vs. 17/40) and segments (91/649 vs. 79/649) with LGE with higher level of certainty (2.9 [2.8–3.0] vs. 2.7 [2.5–2.8], P = 0.0185). Interobserver agreement was good to excellent for LGE detection. Conclusion: TRAMINER provides better contrast between LGE and blood and consequently may have increased ability to discriminate thin subendocardial and papillary muscle enhancement from the blood signal, which can have an indistinct appearance using SIR. Level of Evidence: 2. J. MAGN. RESON. IMAGING 2017;45:1429–1437.

Muscogiuri, G., Rehwald, W., Joseph Schoepf, U., Suranyi, P., Litwin, S., De Cecco, C., et al. (2017). T(Rho) and magnetization transfer and INvErsion recovery (TRAMINER)-prepared imaging: a novel contrast-enhanced flow-independent dark-blood technique for the evaluation of myocardial late gadolinium enhancement in patients with myocardial infarction. JOURNAL OF MAGNETIC RESONANCE IMAGING, 45(5), 1429-1437 [10.1002/jmri.25498].

T(Rho) and magnetization transfer and INvErsion recovery (TRAMINER)-prepared imaging: a novel contrast-enhanced flow-independent dark-blood technique for the evaluation of myocardial late gadolinium enhancement in patients with myocardial infarction

Giuseppe Muscogiuri;
2017

Abstract

Purpose: To evaluate a new dark-blood late gadolinium enhancement (LGE) technique called “T(Rho) And Magnetization transfer and INvErsion Recovery” (TRAMINER) for the ability to detect myocardial LGE versus standard “bright-blood” inversion recovery (SIR) imaging. Materials and Methods: This Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study included 40 patients (62 ± 14 years [mean ± standard deviation (SD)], 29 males) with suspected myocardial infarction (MI) referred for the assessment of myocardial viability. The patients underwent a 1.5T cardiac magnetic resonance imaging (MRI) including postcontrast SIR and TRAMINER acquisitions. Normalized images were evaluated by two readers. Subjective (3-point Likert scale) and objective image qualities were compared using Mann–Whitney U-test and paired t-test, respectively. Interobserver agreement, LGE detection rate, and level of certainty were compared using Cohen's kappa, Wilcoxon-test, and Mann–Whitney U-test, respectively. Results are reported as mean ± SD or mean [95% confidence interval]. Results: Overall, image quality was rated similar between TRAMINER and SIR; however, TRAMINER performed better on a visual assessment of the ability to differentiate LGE from blood (Likert scale: 3.0 [3.0–3.0] vs. 2.0 [1.7–2.2], P < 0.0001). TRAMINER provided significantly higher signal intensity range (69.8 ± 10.2 vs. 9.6 ± 7.6, P < 0.0001) and a 4-fold higher signal intensity ratio (4.2 ± 1.9 vs. 1.1 ± 0.1, P < 0.0001) between LGE and blood signals. TRAMINER detected more patients (19/40 vs. 17/40) and segments (91/649 vs. 79/649) with LGE with higher level of certainty (2.9 [2.8–3.0] vs. 2.7 [2.5–2.8], P = 0.0185). Interobserver agreement was good to excellent for LGE detection. Conclusion: TRAMINER provides better contrast between LGE and blood and consequently may have increased ability to discriminate thin subendocardial and papillary muscle enhancement from the blood signal, which can have an indistinct appearance using SIR. Level of Evidence: 2. J. MAGN. RESON. IMAGING 2017;45:1429–1437.
Articolo in rivista - Articolo scientifico
black blood; bright blood; inversion recovery; late gadolinium enhancement; myocardial infarction;
English
2017
45
5
1429
1437
reserved
Muscogiuri, G., Rehwald, W., Joseph Schoepf, U., Suranyi, P., Litwin, S., De Cecco, C., et al. (2017). T(Rho) and magnetization transfer and INvErsion recovery (TRAMINER)-prepared imaging: a novel contrast-enhanced flow-independent dark-blood technique for the evaluation of myocardial late gadolinium enhancement in patients with myocardial infarction. JOURNAL OF MAGNETIC RESONANCE IMAGING, 45(5), 1429-1437 [10.1002/jmri.25498].
File in questo prodotto:
File Dimensione Formato  
Muscogiuri-2017-J Magnet Reson Imag-VoR.pdf

Solo gestori archivio

Descrizione: Original Research Article
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Tutti i diritti riservati
Dimensione 292.17 kB
Formato Adobe PDF
292.17 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/378168
Citazioni
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 32
Social impact