In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an interlaboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses.

Bassinet, C., Woda, C., Bortolin, E., Della Monaca, S., Fattibene, P., Quattrini, M., et al. (2014). Retrospective radiation dosimetry using OSL of electronic components: results of an inter-laboratory comparison. RADIATION MEASUREMENTS, 71, 475-479 [10.1016/j.radmeas.2014.03.016].

Retrospective radiation dosimetry using OSL of electronic components: results of an inter-laboratory comparison

GALLI, ANNA;PANZERI, LAURA;MARTINI, MARCO
2014

Abstract

In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an interlaboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses.
Articolo in rivista - Articolo scientifico
OSL, retrospective dosimetry
English
2014
71
475
479
none
Bassinet, C., Woda, C., Bortolin, E., Della Monaca, S., Fattibene, P., Quattrini, M., et al. (2014). Retrospective radiation dosimetry using OSL of electronic components: results of an inter-laboratory comparison. RADIATION MEASUREMENTS, 71, 475-479 [10.1016/j.radmeas.2014.03.016].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/84108
Citazioni
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 68
Social impact