This research concerns the experimental and theoretical analysis of an SF6 radio-frequency (RF) discharge at Low pressure in a small reactor for industrial applications. The plasma is produced in the pressure range of 0.05-1 mbar by a 13.56-MHz RF supplier at moderate power, up to 25 W. The pumping system sustains a flowrate of about 50 cm/s, with residence time in the discharge of about 0.2 s, The discharge parameters have been measured and lie in the range n(e) congruent to 10(7)-10(9) cm(-3), n(i) congruent to 10(10)-10(12) cm(-3), T-e congruent to 5-10 eV. Measurements were performed by means of movable electrostatic probes and of a phodiode. Particular care in the analysis of the data proved necessary due to the presence of a substantial amount of negative ions. On the other hand, we have performed simulations of the discharge composition through the implementation of a suitable numerical model of the chemical kinetics in the device. On the basis of the experiments a comparison of charge and neutral species production with those predicted by the theory was performed, and a more realistic description of the involved phenomena was obtained. In particular, several assumptions concerning the ion diffusion coefficient were tested, allowing us to pin down the relative importance of transport and bulk processes in the discharge state.

Riccardi, C., Barni, R., De Colle, F., Fontanesi, M. (2000). Modeling and diagnostic of an SF6 RF plasma at low pressure. IEEE TRANSACTIONS ON PLASMA SCIENCE, 28(1), 278-287 [10.1109/27.842923].

Modeling and diagnostic of an SF6 RF plasma at low pressure

RICCARDI, CLAUDIA;BARNI, RUGGERO;FONTANESI, MARCELLO
2000

Abstract

This research concerns the experimental and theoretical analysis of an SF6 radio-frequency (RF) discharge at Low pressure in a small reactor for industrial applications. The plasma is produced in the pressure range of 0.05-1 mbar by a 13.56-MHz RF supplier at moderate power, up to 25 W. The pumping system sustains a flowrate of about 50 cm/s, with residence time in the discharge of about 0.2 s, The discharge parameters have been measured and lie in the range n(e) congruent to 10(7)-10(9) cm(-3), n(i) congruent to 10(10)-10(12) cm(-3), T-e congruent to 5-10 eV. Measurements were performed by means of movable electrostatic probes and of a phodiode. Particular care in the analysis of the data proved necessary due to the presence of a substantial amount of negative ions. On the other hand, we have performed simulations of the discharge composition through the implementation of a suitable numerical model of the chemical kinetics in the device. On the basis of the experiments a comparison of charge and neutral species production with those predicted by the theory was performed, and a more realistic description of the involved phenomena was obtained. In particular, several assumptions concerning the ion diffusion coefficient were tested, allowing us to pin down the relative importance of transport and bulk processes in the discharge state.
Articolo in rivista - Articolo scientifico
capacitively coupled discharges; chemical kinetics; diffusuin and transport; modeling; plasma measurements; radio frequency plasma
English
feb-2000
28
1
278
287
none
Riccardi, C., Barni, R., De Colle, F., Fontanesi, M. (2000). Modeling and diagnostic of an SF6 RF plasma at low pressure. IEEE TRANSACTIONS ON PLASMA SCIENCE, 28(1), 278-287 [10.1109/27.842923].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/609
Citazioni
  • Scopus 48
  • ???jsp.display-item.citation.isi??? 47
Social impact