The progress on high-rate event recording of data is taken as starting point to revisit the design of fusion neutron spectrometers based on the TOF (time-of-flight) technique. The study performed was aimed at how such instruments for optimized rate (TOFOR) can be further developed to enhance the plasma diagnostic capabilities based on measurement of the 2.5 MeV dd neutron emission from D plasmas, especially the weak spectral components that depend on discrimination of extraneous events. This paper describes a design (TOFOR II) adapted for use with digital wave form recording of all detector pulses providing information on both amplitude (pulse height) and timing. The results of simulations are presented and the performance enhancement is assessed in comparison to the present. © 2014 AIP Publishing LLC.

Zhang, X., Källne, J., Gorini, G., Nocente, M., Fan, T., Yuan, X., et al. (2014). Second generation fusion neutron time-of-flight spectrometer at optimized rate for fully digital data acquisition. REVIEW OF SCIENTIFIC INSTRUMENTS, 85(4) [10.1063/1.4869804].

Second generation fusion neutron time-of-flight spectrometer at optimized rate for fully digital data acquisition

GORINI, GIUSEPPE;NOCENTE, MASSIMO;
2014

Abstract

The progress on high-rate event recording of data is taken as starting point to revisit the design of fusion neutron spectrometers based on the TOF (time-of-flight) technique. The study performed was aimed at how such instruments for optimized rate (TOFOR) can be further developed to enhance the plasma diagnostic capabilities based on measurement of the 2.5 MeV dd neutron emission from D plasmas, especially the weak spectral components that depend on discrimination of extraneous events. This paper describes a design (TOFOR II) adapted for use with digital wave form recording of all detector pulses providing information on both amplitude (pulse height) and timing. The results of simulations are presented and the performance enhancement is assessed in comparison to the present. © 2014 AIP Publishing LLC.
Articolo in rivista - Articolo scientifico
Instrumentation
English
2014
85
4
043503
none
Zhang, X., Källne, J., Gorini, G., Nocente, M., Fan, T., Yuan, X., et al. (2014). Second generation fusion neutron time-of-flight spectrometer at optimized rate for fully digital data acquisition. REVIEW OF SCIENTIFIC INSTRUMENTS, 85(4) [10.1063/1.4869804].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/59046
Citazioni
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 19
Social impact