OBJECTIVE: To assess selected physiological effects of non-invasive continuous positive airway pressure delivered by head helmet (CPAPH), a special interface device designed to completely contain the head of the patient, compared to face mask (CPAPM). DESIGN: Randomized physiological study. SETTING: University research laboratory. PATIENTS: Eight healthy volunteers. INTERVENTION: Continuous positive airway pressure delivered by face mask and CPAPH in random order. Three gas flow rates (20-30-40 l/min and 30-45-60 l/min, respectively, for CPAPM and (CPAPH) and four CPAP levels (0-5-10-15 cmH2O) were employed in a randomized sequence. MEASUREMENTS AND RESULTS: In each patient we monitored airway pressure, esophageal pressure, expiratory flow, and inspiratory and expiratory CO2 concentration. End-expiratory lung volume changes from CPAP 0 were measured by inductance plethysmography. The application of increased levels of CPAP resulted in a significant increase in end-expiratory lung volume, similar for CPAPH and CPAPM. Inspiratory changes of airway pressure were comparable for the two CPAP modes. Inspiratory CO2 concentration was higher during CPAPH (significantly decreased at increased gas flow rates), compared to CPAPM. CONCLUSIONS: Continuous positive airway pressure delivered by head helmet is as effective as CPAPM in increasing end-expiratory lung volume and in compensating for airway pressure changes without the need of a reservoir bag. Higher gas flow rates are necessary to maintain a relatively low inspiratory CO2 concentration

Patroniti, N., Foti, G., Manfio, A., Coppo, A., Bellani, G., Pesenti, A. (2003). Head helmet versus face mask for non-invasive continuous positive airway pressure: a physiological study. INTENSIVE CARE MEDICINE, 29(10), 1680-1687 [10.1007/s00134-003-1931-8].

Head helmet versus face mask for non-invasive continuous positive airway pressure: a physiological study

PATRONITI, NICOLO' ANTONINO;FOTI, GIUSEPPE;BELLANI, GIACOMO;PESENTI, ANTONIO MARIA
2003

Abstract

OBJECTIVE: To assess selected physiological effects of non-invasive continuous positive airway pressure delivered by head helmet (CPAPH), a special interface device designed to completely contain the head of the patient, compared to face mask (CPAPM). DESIGN: Randomized physiological study. SETTING: University research laboratory. PATIENTS: Eight healthy volunteers. INTERVENTION: Continuous positive airway pressure delivered by face mask and CPAPH in random order. Three gas flow rates (20-30-40 l/min and 30-45-60 l/min, respectively, for CPAPM and (CPAPH) and four CPAP levels (0-5-10-15 cmH2O) were employed in a randomized sequence. MEASUREMENTS AND RESULTS: In each patient we monitored airway pressure, esophageal pressure, expiratory flow, and inspiratory and expiratory CO2 concentration. End-expiratory lung volume changes from CPAP 0 were measured by inductance plethysmography. The application of increased levels of CPAP resulted in a significant increase in end-expiratory lung volume, similar for CPAPH and CPAPM. Inspiratory changes of airway pressure were comparable for the two CPAP modes. Inspiratory CO2 concentration was higher during CPAPH (significantly decreased at increased gas flow rates), compared to CPAPM. CONCLUSIONS: Continuous positive airway pressure delivered by head helmet is as effective as CPAPM in increasing end-expiratory lung volume and in compensating for airway pressure changes without the need of a reservoir bag. Higher gas flow rates are necessary to maintain a relatively low inspiratory CO2 concentration
Articolo in rivista - Articolo scientifico
continuous positive airway pressure; head helmet; face mask; hypoxemic respiratory failure; healthy volunteers
English
2003
29
10
1680
1687
none
Patroniti, N., Foti, G., Manfio, A., Coppo, A., Bellani, G., Pesenti, A. (2003). Head helmet versus face mask for non-invasive continuous positive airway pressure: a physiological study. INTENSIVE CARE MEDICINE, 29(10), 1680-1687 [10.1007/s00134-003-1931-8].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/4695
Citazioni
  • Scopus 121
  • ???jsp.display-item.citation.isi??? 101
Social impact