Dual X-ray absorptiometry (DXA) instruments are now able to evaluate bone mineral density (BMD) of bone surrounding metal implants. The assessment of BMD around prosthetic components could provide additional information for the follow-up of total hip arthroplasty (THA). In this study, we evaluated the potential application of DXA in the field of THA. BMD was measured in the proximal femur of both THA and THA-free sides in 14 postmenopausal women 6- 18 months after THA. The explored segment was divided into seven zones as proposed by Gruen et al. [18]. The precision error of BMD measurements ranged from 1.8 to 6.8% on the THA side and from 1.1 to 2% to the THA-free side. The reduction of BMD of the THA versus the THA-free side was significant in all seven zones (P < 0.01, t-test for paired data). These results showed significant differences in BMD around femoral components of THA with respect to contralateral healthy side, and demonstrate the sensitivity of DXA for detecting these changes

Trevisan, C., Bigoni, M., Cherubini, R., Steiger, P., Randelli, G., Ortolani, S. (1993). Dual X-ray absorptiometry for the evaluation of bone density from the proximal femur after total hip arthroplasty: Analysis protocols and reproducibility. CALCIFIED TISSUE INTERNATIONAL, 53(3), 158-161 [10.1007/BF01321831].

Dual X-ray absorptiometry for the evaluation of bone density from the proximal femur after total hip arthroplasty: Analysis protocols and reproducibility

Bigoni, M;
1993

Abstract

Dual X-ray absorptiometry (DXA) instruments are now able to evaluate bone mineral density (BMD) of bone surrounding metal implants. The assessment of BMD around prosthetic components could provide additional information for the follow-up of total hip arthroplasty (THA). In this study, we evaluated the potential application of DXA in the field of THA. BMD was measured in the proximal femur of both THA and THA-free sides in 14 postmenopausal women 6- 18 months after THA. The explored segment was divided into seven zones as proposed by Gruen et al. [18]. The precision error of BMD measurements ranged from 1.8 to 6.8% on the THA side and from 1.1 to 2% to the THA-free side. The reduction of BMD of the THA versus the THA-free side was significant in all seven zones (P < 0.01, t-test for paired data). These results showed significant differences in BMD around femoral components of THA with respect to contralateral healthy side, and demonstrate the sensitivity of DXA for detecting these changes
Articolo in rivista - Articolo scientifico
adult; article; bone density; bone mass; bone mineral; bone scintiscanning; clinical article; endoprosthesis loosening; female; femur; human; priority journal; prognosis; reproducibility; total hip prosthesis, Aged; Bone Density; Densitometry, X-Ray; Female; Femur; Follow-Up Studies; Hip Prosthesis; Human; Lumbar Vertebrae; Middle Age; Reproducibility of Results
English
1993
53
3
158
161
none
Trevisan, C., Bigoni, M., Cherubini, R., Steiger, P., Randelli, G., Ortolani, S. (1993). Dual X-ray absorptiometry for the evaluation of bone density from the proximal femur after total hip arthroplasty: Analysis protocols and reproducibility. CALCIFIED TISSUE INTERNATIONAL, 53(3), 158-161 [10.1007/BF01321831].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/38400
Citazioni
  • Scopus 73
  • ???jsp.display-item.citation.isi??? 60
Social impact