We report a rather simple method to determine glucose concentration in serum, using isotope dilution mass spectrometry and [13C6]glucose as internal standard. The procedure involves a single step of sample purification and the conversion of the analyte into its aldononitrile pentaacetate. The between-day and within-day contribution to total variance for a single measurement was determined by assaying Standard Reference Material (SRM) 909 serum. The method was then applied to measurement of glucose concentration in three lyophilized sera: SRM 909 and two other commercially available sera. In the two studies, the concentration of SRM 909 serum was found to be 0.8% above and 0.3% below the reported value (6.25 mmol/L), respectively; the overall coefficient of variation for determinations in all sera ranged from 0.37% to 0.56%. The precision and the accuracy of the method satisfy the requirements for a Definitive Method.

Magni, F., Paroni, R., Bonini, P., Kienle, M. (1992). Determination of serum glucose by isotope dilution mass spectrometry: candidate definitive method. CLINICAL CHEMISTRY, 38(3), 381-385 [10.1093/clinchem/38.3.381].

Determination of serum glucose by isotope dilution mass spectrometry: candidate definitive method

MAGNI, FULVIO;
1992

Abstract

We report a rather simple method to determine glucose concentration in serum, using isotope dilution mass spectrometry and [13C6]glucose as internal standard. The procedure involves a single step of sample purification and the conversion of the analyte into its aldononitrile pentaacetate. The between-day and within-day contribution to total variance for a single measurement was determined by assaying Standard Reference Material (SRM) 909 serum. The method was then applied to measurement of glucose concentration in three lyophilized sera: SRM 909 and two other commercially available sera. In the two studies, the concentration of SRM 909 serum was found to be 0.8% above and 0.3% below the reported value (6.25 mmol/L), respectively; the overall coefficient of variation for determinations in all sera ranged from 0.37% to 0.56%. The precision and the accuracy of the method satisfy the requirements for a Definitive Method.
Articolo in rivista - Articolo scientifico
Mass Spectrometry; Humans; Indicator Dilution Techniques; Quality Control; Blood Glucose
English
mar-1992
38
3
381
385
none
Magni, F., Paroni, R., Bonini, P., Kienle, M. (1992). Determination of serum glucose by isotope dilution mass spectrometry: candidate definitive method. CLINICAL CHEMISTRY, 38(3), 381-385 [10.1093/clinchem/38.3.381].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/36193
Citazioni
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 28
Social impact