Introduction: The clinical use of serial quantitative computed tomography (CT) to characterize lung disease and guide the optimization of mechanical ventilation in patients with acute respiratory distress syndrome (ARDS) is limited by the risk of cumulative radiation exposure and by the difficulties and risks related to transferring patients to the CT room. We evaluated the effects of tube current-time product (mAs) variations on quantitative results in healthy lungs and in experimental ARDS in order to support the use of low-dose CT for quantitative analysis. Methods: In 14 sheep chest CT was performed at baseline and after the induction of ARDS via intravenous oleic acid injection. For each CT session, two consecutive scans were obtained applying two different mAs: 60 mAs was paired with 140, 15 or 7.5 mAs. All other CT parameters were kept unaltered (tube voltage 120 kVp, collimation 32x0.5 mm, pitch 0.85, matrix 512x512, pixel size 0.625x0.625 mm ). Quantitative results obtained at different mAs were compared via Bland-Altman analysis. Results: Good agreement was observed between 60 mAs and 140 mAs and between 60 mAs and 15 mAs (all biases less than 1%). A further reduction of mAs to 7.5 mAs caused an increase in the bias of poorly and non aerated tissue (-2.9 and 2.4%, respectively) and determined a significant widening of the limits of agreement for the same compartments (-10.5 - 4.8 % for poorly aerated and -5.9 - 10.8% for non aerated tissue). Estimated mean effective dose at 140, 60, 15 and 7.5 mAs corresponded to 17.8, 7.4, 2.0 and 0.9 millisievert, respectively. Image noise of scans performed at 140, 60, 15 and 7.5 mAs corresponded to 10, 16, 38 and 74 Hounsfield Units, respectively. Conclusions: A reduction of effective dose up to 70% has been achieved with minimal effects on lung quantitative results. Low-dose computed tomography provides accurate quantitative results and could be used to characterize lung compartment distribution and possibly monitor time-course of ARDS with a lower risk of exposure to ionizing radiation. A further radiation dose reduction is associated with lower accuracy in quantitative results

Vecchi, V., Langer, T., Bellomi, M., Rampinelli, C., Chung, K., Cancio, L., et al. (2013). Low-dose CT for quantitative analysis in acute respiratory distress syndrome. CRITICAL CARE, 17(4), 1-10 [10.1186/cc12866].

Low-dose CT for quantitative analysis in acute respiratory distress syndrome

Langer, T
;
2013

Abstract

Introduction: The clinical use of serial quantitative computed tomography (CT) to characterize lung disease and guide the optimization of mechanical ventilation in patients with acute respiratory distress syndrome (ARDS) is limited by the risk of cumulative radiation exposure and by the difficulties and risks related to transferring patients to the CT room. We evaluated the effects of tube current-time product (mAs) variations on quantitative results in healthy lungs and in experimental ARDS in order to support the use of low-dose CT for quantitative analysis. Methods: In 14 sheep chest CT was performed at baseline and after the induction of ARDS via intravenous oleic acid injection. For each CT session, two consecutive scans were obtained applying two different mAs: 60 mAs was paired with 140, 15 or 7.5 mAs. All other CT parameters were kept unaltered (tube voltage 120 kVp, collimation 32x0.5 mm, pitch 0.85, matrix 512x512, pixel size 0.625x0.625 mm ). Quantitative results obtained at different mAs were compared via Bland-Altman analysis. Results: Good agreement was observed between 60 mAs and 140 mAs and between 60 mAs and 15 mAs (all biases less than 1%). A further reduction of mAs to 7.5 mAs caused an increase in the bias of poorly and non aerated tissue (-2.9 and 2.4%, respectively) and determined a significant widening of the limits of agreement for the same compartments (-10.5 - 4.8 % for poorly aerated and -5.9 - 10.8% for non aerated tissue). Estimated mean effective dose at 140, 60, 15 and 7.5 mAs corresponded to 17.8, 7.4, 2.0 and 0.9 millisievert, respectively. Image noise of scans performed at 140, 60, 15 and 7.5 mAs corresponded to 10, 16, 38 and 74 Hounsfield Units, respectively. Conclusions: A reduction of effective dose up to 70% has been achieved with minimal effects on lung quantitative results. Low-dose computed tomography provides accurate quantitative results and could be used to characterize lung compartment distribution and possibly monitor time-course of ARDS with a lower risk of exposure to ionizing radiation. A further radiation dose reduction is associated with lower accuracy in quantitative results
Articolo in rivista - Articolo scientifico
ARDS, respiratory failure, CT scan
English
2013
17
4
1
10
R183
reserved
Vecchi, V., Langer, T., Bellomi, M., Rampinelli, C., Chung, K., Cancio, L., et al. (2013). Low-dose CT for quantitative analysis in acute respiratory distress syndrome. CRITICAL CARE, 17(4), 1-10 [10.1186/cc12866].
File in questo prodotto:
File Dimensione Formato  
239_vecchi_cc12866_2013.pdf

Solo gestori archivio

Dimensione 584.54 kB
Formato Adobe PDF
584.54 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/252751
Citazioni
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 19
Social impact