The Mosca-B-Detector (Materia OSCura a Bolle, dark matter bubble detector) is a geyser bubble chamber based on a superheated C3F8 volume in a closed vessel which aims to detect Dark Matter Weakly Interacting Massive Particles (WIMPs). When a particle interacts with the fluorine atoms, energy is released in small volume that acts as a nucleation site, producing a bubble and an acoustic signal, which are sensed by means of a set of ultrasound sensors and high-speed cameras. Each event, detected by threshold crossing approach, presents a specific acoustic signature (signal amplitude, duration and bandwidth) that can be used to separate the involved particles from background noise and thus detects an eventual WIMP interaction. However, the very low event rate (few events/day) along with weak signal amplitude (100 - 101 μV0-PEAK range) and small intrinsic sensor noise (2.3 nV/√Hz), forces strong constraints on the electronics noise to maximize the sensitivity of the detector to weak signals (thus minimizing false negatives/missed detections).This work presents the design of a 45 dB 0.3 nV/√Hz Input Referred Noise analog front-end specifically dedicated to acoustic particle detection applications. The final 0.2 dB Noise Figure allows to set a 7-sigma threshold as low as 14μV (input-referred), thus allowing to observe the weakest events and thus maximize the detector sensitivity.

Vallicelli, E., Gelmi, L., Bertoni, R., Fulgione, W., Tambaro, M., Baschirotto, A., et al. (2019). A 0.3nV/√ Hz Input-Referred-Noise Analog Front-End for Weakly-Interacting-Massive-Particles (WIMPs) Acoustic Sensing in Bubbles-Chamber Detectors. In PRIME 2019 - 15th Conference on Ph.D. Research in Microelectronics and Electronics, Proceedings (pp.197-200). 345 E 47TH ST, NEW YORK, NY 10017 USA : Institute of Electrical and Electronics Engineers Inc. [10.1109/PRIME.2019.8787765].

A 0.3nV/√ Hz Input-Referred-Noise Analog Front-End for Weakly-Interacting-Massive-Particles (WIMPs) Acoustic Sensing in Bubbles-Chamber Detectors

Vallicelli, Elia A.
Primo
;
Tambaro, Mattia;Baschirotto, Andrea;De Matteis, Marcello
2019

Abstract

The Mosca-B-Detector (Materia OSCura a Bolle, dark matter bubble detector) is a geyser bubble chamber based on a superheated C3F8 volume in a closed vessel which aims to detect Dark Matter Weakly Interacting Massive Particles (WIMPs). When a particle interacts with the fluorine atoms, energy is released in small volume that acts as a nucleation site, producing a bubble and an acoustic signal, which are sensed by means of a set of ultrasound sensors and high-speed cameras. Each event, detected by threshold crossing approach, presents a specific acoustic signature (signal amplitude, duration and bandwidth) that can be used to separate the involved particles from background noise and thus detects an eventual WIMP interaction. However, the very low event rate (few events/day) along with weak signal amplitude (100 - 101 μV0-PEAK range) and small intrinsic sensor noise (2.3 nV/√Hz), forces strong constraints on the electronics noise to maximize the sensitivity of the detector to weak signals (thus minimizing false negatives/missed detections).This work presents the design of a 45 dB 0.3 nV/√Hz Input Referred Noise analog front-end specifically dedicated to acoustic particle detection applications. The final 0.2 dB Noise Figure allows to set a 7-sigma threshold as low as 14μV (input-referred), thus allowing to observe the weakest events and thus maximize the detector sensitivity.
slide + paper
JFET circuits; low-noise amplifiers; Piezoelectric transducers; Ultrasonic transducers;
English
15th Conference on Ph.D. Research in Microelectronics and Electronics, PRIME 2019
2019
PRIME 2019 - 15th Conference on Ph.D. Research in Microelectronics and Electronics, Proceedings
9781728135496
2019
197
200
8787765
none
Vallicelli, E., Gelmi, L., Bertoni, R., Fulgione, W., Tambaro, M., Baschirotto, A., et al. (2019). A 0.3nV/√ Hz Input-Referred-Noise Analog Front-End for Weakly-Interacting-Massive-Particles (WIMPs) Acoustic Sensing in Bubbles-Chamber Detectors. In PRIME 2019 - 15th Conference on Ph.D. Research in Microelectronics and Electronics, Proceedings (pp.197-200). 345 E 47TH ST, NEW YORK, NY 10017 USA : Institute of Electrical and Electronics Engineers Inc. [10.1109/PRIME.2019.8787765].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/240386
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact