The collection of atmospheric particles on not-filtering substrates via dry deposition, and the subsequent study of the particle-induced material decay, is trivial due to the high number of variables simultaneously acting on the investigated surface. This work reports seasonally resolved data of chemical composition and size distribution of particulate matter deposed on stone and surrogate surfaces obtained using a new method, especially developed at this purpose. A “Deposition Box” was designed allowing the particulate matter dry deposition to occur selectively removing, at the same time, variables that can mask the effect of airborne particles on material decay. A pitched roof avoided rainfall and wind variability; a standardised gentle air exchange rate ensured a continuous “sampling” of ambient air leaving unchanged the sampled particle size distribution and, at the same time, leaving quite calm condition inside the box, allowing the deposition to occur. Thus, the “Deposition Box” represents an affordable tool that can be used complementary to traditional exposure systems. With this system, several exposure campaigns, involving investigated stone materials (ISMs) (Carrara Marble, Botticino limestone, Noto calcarenite and Granite) and surrogate (Quartz, PTFE, and Aluminium) substrates, have been performed in two different sites placed in Milan (Italy) inside and outside the low emission zone. Deposition rates (30–90 μg cm−2 month−1) showed significant differences between sites and seasons, becoming less evident considering long-period exposures due to a positive feedback on the deposition induced by the deposited particles. Similarly, different stone substrates influenced the deposition rates too. The collected deposits have been observed with optical and scanning electron microscopes and analysed by ion chromatography. Ion deposition rates were similar in the two sites during winter, whereas it was greater outside the low emission zone during summer and considering the long-period exposure. The dimensional distribution of the collected deposits showed a significant presence of fine particles in agreement with deposition rate of the ionic fraction. The obtained results allowed to point out the role of the fine particles fraction and the importance of making seasonal studies.

Ferrero, L., Casati, M., Nobili, L., D’Angelo, L., Rovelli, G., Sangiorgi, G., et al. (2018). Chemically and size-resolved particulate matter dry deposition on stone and surrogate surfaces inside and outside the low emission zone of Milan: application of a newly developed “Deposition Box”. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL, 25(10), 9402-9415 [10.1007/s11356-018-1220-2].

Chemically and size-resolved particulate matter dry deposition on stone and surrogate surfaces inside and outside the low emission zone of Milan: application of a newly developed “Deposition Box”

Ferrero, Luca
Primo
;
D’Angelo, Luca;Rovelli, Grazia;Sangiorgi, Giorgia;Rizzi, Cristiana;Sansonetti, Antonio;Bolzacchini, Ezio;
2018

Abstract

The collection of atmospheric particles on not-filtering substrates via dry deposition, and the subsequent study of the particle-induced material decay, is trivial due to the high number of variables simultaneously acting on the investigated surface. This work reports seasonally resolved data of chemical composition and size distribution of particulate matter deposed on stone and surrogate surfaces obtained using a new method, especially developed at this purpose. A “Deposition Box” was designed allowing the particulate matter dry deposition to occur selectively removing, at the same time, variables that can mask the effect of airborne particles on material decay. A pitched roof avoided rainfall and wind variability; a standardised gentle air exchange rate ensured a continuous “sampling” of ambient air leaving unchanged the sampled particle size distribution and, at the same time, leaving quite calm condition inside the box, allowing the deposition to occur. Thus, the “Deposition Box” represents an affordable tool that can be used complementary to traditional exposure systems. With this system, several exposure campaigns, involving investigated stone materials (ISMs) (Carrara Marble, Botticino limestone, Noto calcarenite and Granite) and surrogate (Quartz, PTFE, and Aluminium) substrates, have been performed in two different sites placed in Milan (Italy) inside and outside the low emission zone. Deposition rates (30–90 μg cm−2 month−1) showed significant differences between sites and seasons, becoming less evident considering long-period exposures due to a positive feedback on the deposition induced by the deposited particles. Similarly, different stone substrates influenced the deposition rates too. The collected deposits have been observed with optical and scanning electron microscopes and analysed by ion chromatography. Ion deposition rates were similar in the two sites during winter, whereas it was greater outside the low emission zone during summer and considering the long-period exposure. The dimensional distribution of the collected deposits showed a significant presence of fine particles in agreement with deposition rate of the ionic fraction. The obtained results allowed to point out the role of the fine particles fraction and the importance of making seasonal studies.
Articolo in rivista - Articolo scientifico
Aerosols; Chemical composition; Dry deposition; Material decay; Size distribution;
Aerosols; Chemical composition; Dry deposition; Material decay; Size distribution; Environmental Chemistry; Pollution; Health, Toxicology and Mutagenesis
English
2018
25
10
9402
9415
reserved
Ferrero, L., Casati, M., Nobili, L., D’Angelo, L., Rovelli, G., Sangiorgi, G., et al. (2018). Chemically and size-resolved particulate matter dry deposition on stone and surrogate surfaces inside and outside the low emission zone of Milan: application of a newly developed “Deposition Box”. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL, 25(10), 9402-9415 [10.1007/s11356-018-1220-2].
File in questo prodotto:
File Dimensione Formato  
ESPR-2018-Ferrero-Deposition Box.pdf

Solo gestori archivio

Descrizione: Articolo
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 2.6 MB
Formato Adobe PDF
2.6 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/189230
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
Social impact