Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
Neutral B meson oscillations in the Bs0 - Bs0 and Bd0 - Bd0 systems were studied using a sample of about 4.0 million hadronic Z decays recorded by the DELPHI detector between 1992 and 2000. Events with a high transverse momentum lepton were removed and a sample of 770 k events with an inclusively reconstructed vertex was selected. The mass difference between the two physical states in the Bd0 - Bs0 system was measured to be: Δmd = (0.531 = 0.025(stat.) ± 0.007(syst.))ps-1. The following limit on the width difference of these states was also obtained: |ΔΓBd|/ΓBd < 0.18 at 95% CL. As no evidence for Bs0 - Bs0 oscillations was found, a limit on the mass difference of the two physical states was given: Δms > 5.0 ps-1 at 95% CL. The corresponding sensitivity of this analysis is equal to 6.6 ps-1.
Abdallah, J., Abreu, P., Adam, W., Adzic, P., Albrecht, T., Alderweireld, T., et al. (2003). Search for Bs0 - Bs0 oscillations and a measurement of Bd0 - Bd0 oscillations using events with an inclusively reconstructed vertex: The Delphi collaboration. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 28(2), 155-173 [10.1140/epjc/s2003-01183-7].
Search for Bs0 - Bs0 oscillations and a measurement of Bd0 - Bd0 oscillations using events with an inclusively reconstructed vertex: The Delphi collaboration
Neutral B meson oscillations in the Bs0 - Bs0 and Bd0 - Bd0 systems were studied using a sample of about 4.0 million hadronic Z decays recorded by the DELPHI detector between 1992 and 2000. Events with a high transverse momentum lepton were removed and a sample of 770 k events with an inclusively reconstructed vertex was selected. The mass difference between the two physical states in the Bd0 - Bs0 system was measured to be: Δmd = (0.531 = 0.025(stat.) ± 0.007(syst.))ps-1. The following limit on the width difference of these states was also obtained: |ΔΓBd|/ΓBd < 0.18 at 95% CL. As no evidence for Bs0 - Bs0 oscillations was found, a limit on the mass difference of the two physical states was given: Δms > 5.0 ps-1 at 95% CL. The corresponding sensitivity of this analysis is equal to 6.6 ps-1.
Abdallah, J., Abreu, P., Adam, W., Adzic, P., Albrecht, T., Alderweireld, T., et al. (2003). Search for Bs0 - Bs0 oscillations and a measurement of Bd0 - Bd0 oscillations using events with an inclusively reconstructed vertex: The Delphi collaboration. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 28(2), 155-173 [10.1140/epjc/s2003-01183-7].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/155931
Citazioni
26
26
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.